Skip to content

OSC Device User Guide

Use the OSC device tab to map controls from a touch panel, another app, or a script. GremlinEx (GEX) receives Open Sound Control messages over UDP. A message has an address such as /gex/test/button and can carry arguments such as a button state or a fader position. OSC 1.0 specification

Connect the sender to GEX

  1. Open Options → Modules and enable OSC. Restart GEX if you changed the setting.
  2. Open Options → OSC/MIDI and check Enable OSC. Note the GremlinEx IP and Input port. The default UDP input port is 8000.
  3. Set your panel or app’s OSC destination to that IP and input port. For a panel on another device, use Select next to GremlinEx IP to choose the GEX computer’s LAN address. A sender on the same PC can send to the displayed address too. Use 127.0.0.1 if GEX is listening on loopback.
  4. If Windows Firewall blocks a sender on your LAN, allow inbound UDP to the selected input port on the private network.

Output IP and Output port are defaults for messages sent from GEX. The default output port is 8001. Use the receiving app’s listen port when sending feedback.

Add an OSC input

  1. Open your profile, select the edit mode, and open the OSC tab.
  2. Click Add. In OSC Input Mapper, enter the address in Cmd, including the leading slash. To learn an address and its arguments, click Listen for input, then operate the panel control once. The listener shows the IP and port it is using.
  3. Select Message only so messages with the same address can carry different values. Select the Action mode for the control. For a captured message with several arguments, choose the one to use under Source. For example, you can add two axis inputs for an XY pad with the same address and select a different argument on each row.
  4. Click OK. Select the input row, add a Basic container and an action, then save and activate the profile to test it.
Sender Input setup Result
Momentary button or switch that sends 1 and 0 Select Button and leave Trigger on message off. A nonzero value presses the button. Zero releases it.
Command with no arguments Select Button and enable Trigger on message. Set the release delay. GEX presses the button when the message arrives and releases it after the delay. Autorelease on no arg messages in Options → OSC/MIDI also enables this behavior for argument-free button messages.
Fader or slider that sends a value from 0.0 to 1.0 Select Axis and choose the numeric argument under Source if the message has more than one. GEX maps 0.0 to −1.0, 0.5 to center, and 1.0 to +1.0. Attach Virtual Remap to drive an output axis.
Numeric update you want to handle as a press Select Change. GEX emits a press for each matching numeric message, including zero. Use a press-triggered action.

Bitfocus Companion example

For Stream Deck setup and the full button walkthrough, see the Bitfocus Companion Setup Guide.

In this setup, Companion and GEX run on the same Windows PC. Companion sends button events to GEX, and GEX uses the profile’s keyboard ex bindings to control Star Citizen.

Connection Settings from this setup
Companion Generic → OSC connection, named osc UDP, target 192.168.1.95:8000, feedback listener enabled on UDP 8001.
GEX Options → OSC/MIDI GremlinEx IP 192.168.1.95, Input port 8000.
Companion web admin http://127.0.0.1:8010 on this PC. Open it to edit the connection and buttons.

Use your GEX computer’s selected listener address in Companion’s target settings. 192.168.1.95 is the address used in this example. Bitfocus Generic OSC documentation

Toggle the landing gear

  1. In Companion, edit the gear button. Under Press actions, add the osc connection’s Send float action with path /gear_toggle and value 1.0. Under Release actions, use Send float with the same path and value 0.0.
  2. In GEX, open the SC Ex profile’s Default mode and select /gear_toggle in the OSC tab. To recreate the input in another profile, use Message only, Button, and the first argument. Leave Trigger on message off because Companion sends the release.
  3. Add Map to Keyboard/Mouse Ex in a Basic container. Select N, choose Pulse, set the duration to 125 ms, and configure the action to execute on press only. The saved SC Ex mapping also plays a sound on press to acknowledge the command. Map to Keyboard/Mouse Ex User Guide
  4. Verify that N is bound to the landing gear in Star Citizen, activate the profile, and press the Companion button in the game. GEX sends one key pulse even if you hold the Companion button. Releasing the Companion button resets the OSC input for the next press.

More SC Ex button mappings

These Companion buttons also send a float 1.0 on press and 0.0 on release. In GEX they use Message only, Button, and Map to Keyboard/Mouse Ex. Use the keys assigned in your Star Citizen controls if they differ from the saved profile.

Star Citizen control OSC path SC Ex keyboard output Trigger on message
Toggle ship lights /lights_toggle L, Hold Off
Toggle VTOL /vtol_toggle K, Hold On, with a 250 ms autorelease delay
Flight ready /flight_ready Right Alt + R, Hold Off

These mappings send keyboard input. For commands advertised by the game’s local server or for feedback driven by actual ship state, see the Star Citizen Device User Guide.

Send a profile-start message back to Companion

SC Ex includes a Map to OSC Ex action on Profile Start. It sends /switch_sc with no arguments to 192.168.1.95:8001. The Companion osc connection listens for that path with Listen for OSC messages (No Arguments) feedback. To recreate the route, set the action target to your Companion computer’s address and its Feedback Port, then match the path in the Companion feedback. Send feedback to a panel

Test a button from the same PC

Create a Button input with address /gex/test/button. Add Play Sound/TTS with a short sound and enable Execute on press only. Save and activate the profile. Send an OSC integer 1 and then 0 from your panel, or run this Python 3 example. Replace the IP and port with the values in Options → OSC/MIDI.

import socket
import struct
import time


def osc_string(value):
    data = value.encode("ascii") + b"\0"
    return data + b"\0" * (-len(data) % 4)


destination = ("127.0.0.1", 8000)
header = osc_string("/gex/test/button") + osc_string(",i")
with socket.socket(socket.AF_INET, socket.SOCK_DGRAM) as sender:
    sender.sendto(header + struct.pack(">i", 1), destination)
    time.sleep(0.2)
    sender.sendto(header + struct.pack(">i", 0), destination)

You should hear the sound once. The input should return to released when the second message arrives. Play Sound/TTS User Guide

Import several inputs

Click Import on the OSC tab and paste one address per line. Use B for a button, BNP for an autorelease button, A for an axis, or C for Change. An address without a suffix defaults to a button.

/panel/lights B
/panel/gear/pulse BNP
/panel/throttle A
/panel/selector C

Import adds input definitions to the selected mode. Add actions to the resulting rows and save the profile.

Send feedback to a panel

To drive a panel indicator from a GEX mapping, add Map to OSC Ex to the source control. Set Target IP and Target Port to the panel’s OSC listener. Enter its address in Command, use Add Argument for the value it expects, then click Test and check the panel. Use a separate feedback address if the panel echoes updates back to GEX. OSC actions

Troubleshooting

Symptom Check
The OSC tab is missing Check Options → Modules → OSC and restart GEX. Also check the device visibility filter.
The listener captures nothing Check the sender’s destination against the IP and port shown by the listener. Use UDP, check the firewall for a LAN sender, and make sure another program has not taken that IP and port.
Capture works but the action does nothing Activate the profile in the mode containing the mapping. Check the address, selected argument, action mode, and press/release settings.
A button stays pressed Send a zero value to release it, or use autorelease for a sender that only sends pulses.
The fader never reaches center or the endpoints Check the selected argument and configure the sender to output 0.0 through 1.0.

To log incoming addresses and arguments, turn on Enable Verbose Log Mode and OSC under Options → Verbosity, then restart GEX and check system.log. Log file location